SDF12D4H-GTEW

The product photo shows a representative model. Specifications and appearance may vary.
Model:SDF12D4H-GTEW
Series:DF12D-GTEW
Catalog PDF
Standards
Classification | Axial Fan |
---|---|
Environmental Measures | Dustproof / Waterproof Type |
Dimensions | □120x41 |
Frame Size | □120 |
Frame Thickness | 41 |
Phase | - |
Power Supply | DC |
Rated Voltage [V] | 12(10.2-13.8) |
Frequency [Hz] | - |
Input power [W] | - |
---|---|
Current [A] | 0.55 |
Rotation speed [min-1] | 2800 |
Maximum Airflow [m3/min] | 2.6 |
Maximum Airflow [CFM] | 91.81 |
Maximum Static Pressure [Pa] | 75.1 |
Maximum Static Pressure [inH2O] | 0.3 |
Noise [dB(A)] | 44 |
Mass [kg] | 0.45 |
Service Life | - |
---|
Safety Standards
[UL] | [CE] | [c-ULus] | [TUV] | [PSE] |
---|---|---|---|---|
- | - | - | - | - |
Specifications
Motor Type | DC fan |
---|---|
Material (Blade) | Resin |
Material (Frame / Case) | Aluminum Die-Cast |
Material (Base [for Non-Frame Models]) | - |
Insulation Class | Class E 120℃ |
Bearing | Ball Bearing |
Operating Temperature Range | -10~+60 |
Operating Humidity Range | 0-98% RH (non-condensing) |
Storage Temperature Range | -30~+85 |
Storage Humidity Range | RH20~85%(non-condensing) |
IP Code | IP65 compliant |
---|---|
Operating Voltage Range | Voltage fluctuation: Within ±15% of rated voltage Continuous operation: At or below rated voltage |
Protection Method | Current cut latch type |
Noise characteristics | Measured at 1.0 m from equipment surface (centerline of air inlet) |
Airflow–Static Pressure Characteristics | Double Chamber Method (AMCA210) |
Dielectric Strength | AC1000V for 1 minute or AC1200V for 1 second (Leakage current ? 0.5 mA, room temperature and humidity, 50Hz) |
Insulation Resistance | 10 MΩ or more when 250 V DC is applied between the windings and the frame under normal ambient conditions. |
Lead Wire Specifications | UL AVLV2 AWG24 +red,-blue,Alarm yellow |
※ Sensor Codes
L: Lock Detection Sensor (Normally Closed)
L-NO: Lock Detection Sensor (Normally Open)
■ Features
Long Life (Expected 100,000 hours), Dust and Water Resistant (IP65)
※ Installation Orientation
When the product is installed with the product label (discharge side) facing upward, water may accumulate in the inner cylindrical section at the center of the blade depending on the amount of water exposure.
Please confirm this condition before adoption.
Option1
Product Name | Finger Guard |
---|---|
Model | IG-120 |
![]() |