Z630F/0C-5-TP

The product photo shows a representative model. Specifications and appearance may vary.
Model:Z630F/0C-5-TP
Series:Z6F-TP
Catalog PDF
Standards
Classification | Cross Flow Fan |
---|---|
Environmental Measures | Standard Type |
Dimensions | φ60x403 |
Frame Size | φ60 |
Frame Thickness | 403 |
Phase | Single-Phase |
Power Supply | AC |
Rated Voltage [V] | 100 |
Frequency [Hz] | 50/60 |
Input power [W] | 34/43 |
---|---|
Current [A] | -/- |
Rotation speed [min-1] | 2500/2650 |
Maximum Airflow [m3/min] | 4.8/4.8 |
Maximum Airflow [CFM] | 169.5/169.5 |
Maximum Static Pressure [Pa] | 88.2/117.6 |
Maximum Static Pressure [inH2O] | 0.35/0.47 |
Noise [dB(A)] | 51/51 |
Mass [kg] | 2.1 |
Service Life | - |
---|
Sensor | |
---|---|
Fan sensorsetting not available. |
Safety Standards
[UL] | [CE] | [c-ULus] | [TUV] | [PSE] |
---|---|---|---|---|
- | - | - | - | - |
Specifications
Motor Type | capacitor-run motor |
---|---|
Material (Blade) | Metal |
Material (Frame / Case) | Metal |
Material (Base [for Non-Frame Models]) | - |
Insulation Class | Class E 120℃ |
Bearing | Ball Bearing |
Operating Temperature Range | -10~+60 |
Operating Humidity Range | RH35~85%(non-condensing) |
Storage Temperature Range | -30~+80 |
Storage Humidity Range | RH20~85%(non-condensing) |
IP Code | - |
---|---|
Operating Voltage Range | Voltage fluctuation: Within ±10% of rated voltage Continuous operation: At or below rated voltage |
Protection Method | Thermal Protection (140℃) |
Noise characteristics | Measured at 1.5 m from equipment surface (centerline of air inlet) |
Airflow–Static Pressure Characteristics | Measured using wind tunnel test equipment based on the previous standard (JIS B 8330). |
Dielectric Strength | AC1500V for 1 minute or AC1800V for 1 second |
Insulation Resistance | 100 MΩ or more when 500 V DC is applied between the windings and the frame under normal ambient conditions. |
Lead Wire Specifications | 20/0.18(0.5sq) blue/black |
Capacitor | |
---|---|
Built-in |
※ Please ensure this product is used in a structure where it cannot be touched by the human body.