200-79-5-TP

The product photo shows a representative model. Specifications and appearance may vary.
Model:200-79-5-TP
Series:200-09-5-TP
Catalog PDF
Standards
Classification | Axial Fan |
---|---|
Environmental Measures | Standard Type |
Dimensions | φ200x83 |
Frame Size | φ200 |
Frame Thickness | 83 |
Phase | Single-Phase |
Power Supply | AC |
Rated Voltage [V] | 230 |
Frequency [Hz] | 50/60 |
Input power [W] | 100/100 |
---|---|
Current [A] | -/- |
Rotation speed [min-1] | 2600/2900 |
Maximum Airflow [m3/min] | 10.5/12.2 |
Maximum Airflow [CFM] | 370.8/430.8 |
Maximum Static Pressure [Pa] | 190.12/78.4 |
Maximum Static Pressure [inH2O] | 0.76/0.31 |
Noise [dB(A)] | 56/58 |
Mass [kg] | 2.9 |
Service Life | - |
---|
Sensor | |
---|---|
Please refer to the fan sensor documentation. |
Safety Standards
[UL] | [CE] | [c-ULus] | [TUV] | [PSE] |
---|---|---|---|---|
- | - | - | - | ◯ |
Specifications
Motor Type | Single-Phase Shaded Pole Induction Motor (2P) |
---|---|
Material (Blade) | Metal |
Material (Frame / Case) | Aluminum Die-Cast |
Material (Base [for Non-Frame Models]) | - |
Insulation Class | Class E 120℃ |
Bearing | Ball Bearing |
Operating Temperature Range | -10~+60 |
Operating Humidity Range | RH35~85%(non-condensing) |
Storage Temperature Range | -30~+80 |
Storage Humidity Range | RH20~85%(non-condensing) |
IP Code | - |
---|---|
Operating Voltage Range | Voltage fluctuation: Within ±10% of rated voltage Continuous operation: At or below rated voltage |
Protection Method | Thermal Protection (135℃) |
Noise characteristics | Measured at 1.5 m from equipment surface (centerline of air inlet) |
Airflow–Static Pressure Characteristics | Double Chamber Method (AMCA210) |
Dielectric Strength | AC1500V for 1 minute or AC1800V for 1 second |
Insulation Resistance | 100 MΩ or more when 500 V DC is applied between the windings and the frame under normal ambient conditions. |
Lead Wire Specifications | 30/0.18(0.75sq)black |
Grounding Specifications | |
---|---|
Grounding terminal with earth screw provided only on 200V class models.Refer to page 17 for details. |
● Reversed Airflow Type (H Type)
Model Example: 200-09H5-TP
Models with reversed airflow include an “H” in the model number. For details, please contact us.